Skip to main content
Join
zipcar-spring-promotion

Klipper inductive probe always triggered

Then attach the log from the session with the old code as well as a session with the new code. Nov 2, 2019 · Hi @4noxx,. Almost everything was discussed before. In Marlin the probe works great. Thank you guys. Apr 8, 2019 · Somehow the pin now stays back when it touched my finger during z homing. I run my printer in this config for months with marlin. I tested continuity from the octopus (PG15) to BAT85. 4 standard, same thing on both boards, its nice to know it was nothing i done wrong but bigtree tech need to test Dec 18, 2022 · If you just want the z position, rather than the z_offset, you could try using the MANUAL_PROBE command, and then use {printer. Here, enthusiasts, hobbyists, and professionals gather to discuss, troubleshoot, and explore everything related to 3D printing with the Ender 3. Now i tried to switch to klipper and Mar 30, 2024 · Basic Information: Printer Model: MCU / Printerboard: klippy. The search function here is very helpful. May 18, 2022 · It's signal and ground that you need! actually, the PB7 "probe" input (J40) on a Octopus (according to BTT's V1. Good luck with your issue, hcet14 Aug 22, 2022 · Thanks! Result: No change in movement however I noticed there is a “!! Endstop x still triggered after retract” message reporting as well. When I lift the print head up I see Dec 23, 2022 · Voron Owner. it is strange when I'm in the homing function the inductive sensor works quite normally Apr 25, 2023 · I'm running a Klicky PCB Board with Stealthburner/Hartk's 2 piece PCB on a Octopus 1. I wonder if it's related to the probe status reading and pin_up_touch_mode_reports_triggered setting. Dec 29, 2021 · I have a 5v BLTouch with the writing "3D Touch" on it. So that the printer does not drive into the bed, you can trigger the bltouch much earlier with your finger. This is not an official Klipper support channel and poorly moderated so ymmv. When I query the probe, it's open. Jan 16, 2023 · I want to edit some of the created mesh-point-values after the probing is done, maybe via an extra macro. The Ender 3 Max uses the same board and also has the CR-Touch. It will move to start homing and then probe wont deploy at all. 3 KB) Describe your issue: …I am using Omron Proximity Switch TL-Q5MC1-Z as my probe. Documentation for BL-Touch initial tests are not correct. Adjusting bed leveling screws using the bed probe¶ This is another way to calibrate the bed level using the bed probe. mcdanlj (Michael K Johnson) December 6, 2022, 4:12am 1. Also tried connecting to gpio22 and gpio6 but nothing will get Klipper to trigger the z endstop. Feb 12, 2023 · Member. Aug 9, 2023 · Basic Information: Printer Model: Voron Tridex MCU / Printerboard: BTT Octopus V1. It always says "open" (or "triggered" if I switch polarity). 88 to 600) it always shows a false detection. Your right offset should be positive in klipper: z_offset: 0. This document is a reference of printer status information available in Klipper macros , display fields, and via the API Server. Endstop phase. Reply. I initially setup my config to always takes 3 samples on a probe, and then take the median result instead of the average. tecno May 7, 2021, 9:36am 4. 5cm above the bed. 03/27. Apr 16, 2024 · The probe drops and raises whenthe printer is turned on, and I am able to raise or lower it through the BL Touch Debug commands, but when I try BLTOUCH_DEBUG COMMAND=touch_mode , then QUERY_PROBE while raising the probe slightly with my nail, it always reports back as ‘open’. See the PROBE command for details on the optional probe parameters. Signal is conectet to the signal pin PB7 (Sensor Port) Jumper set to 24V. Able to manipulate the probe without issues. TLDR: probe_calibration works initially but in any other test the extruder hovers ~0. array81 October 17, 2023, 9:26pm 7. kb-3d. A rare number of old "clone" devices are unable to report when they have successfully raised their Apr 13, 2024 · Please understand that “klipper. O. thanks for the reply. Basically, the sensor oscilates a small electic current in a coil and can detect the resonant frequency of that oscilation. 2. So I still think you just need the '^' to activate the pulls up. 0-klipper. V+ and Ground are wired direcly to the PS. 7k across + and trigger on the probe port also what to do in the config file. This functionality can improve the accuracy of traditional endstop switches. Repeat 3. The text was updated successfully, but these errors were encountered: Interestingly, I'm facing the same problem but with the Reality v4. My Z endstop/probe for Tap are always triggered in klipper and I do not understand why. 0, y=203. Specific to your issue, ensure that as minimum the following values are correct for your specific printer: (1) [stepper_x] and [stepper_y] position_endstop, position_min and position_max; (2) [probe] x_offset and y_offset; (3) [z_tilt] z_positions and points. Feb 23, 2020 · Hello dear community, I have build an Voron 2. Note that # pullup resistor on the board is generally not required. Managed to get the the SFS on the Zero working as it should but the Trident is always showing an Encoder Detection. Remove the metal. It goes through and homes all axis successfully, I can then G28 Z If the above tests okay, but one still receives "Probe triggered prior to movement", "Endstop Z still triggered after retract", or "BLTouch sensor test failed" errors when actually probing, then try increasing the new pin_move_time config setting (see config/example-extras. I went to print tonight on my printer with an inductive Z sensor, and the sensor always reads as triggered. html said, Ender 3 with 4. This coupling is commonly done with magnets though there is support for a variety of designs including servo and stepper actuated couplings. 4 and have tap installed using an OptoTap PCB OPB sensor and Hartk1213 5-24v stealthburner pcb. Sep 29, 2023 · Basic Information: Printer Model: Anycubic Vyper MCU / Printerboard: TMC 2209 Klippy. 7 board and BLTouch 3. 2 board on and Ender 5 Pro. It are always the same, “correction values”, but different ones for the specific probe-points and all of them are relative to the measured values. org This is from my Stock Ender 3v2 4. But the motor still kept going. You specify a pin to use a pull up resistor in klipper by putting a ^ before the pin designation in printer. Nov 5, 2022 · I recently shifted to klipper on base Ender board with 3D Touch and facing the same issue. If the endstop appears inverted (it reports "open" when triggered and vice-versa) then add a "!" to the pin definition (for example, "endstop_pin: ^!ar3"), or remove the "!" if there is already one present. From the official website, v2. log klippy(10). Dec 1, 2022 · Same issue here, sensor seems dead :( , started to face @Bexman issues randomly at the beginning. cfg, I've had several problems. Jun 23, 2022 · jakep_82 June 26, 2022, 5:23am 4. 1 running Klipper and OctoPrint. Dec 1, 2022 · Klipper & BLTouch: How to Make Them Work Together. thanks for your info, i tried an inductive sensor on z axis and i also had not triggered but a limit switch would trigger on z so took the advice given here and swapped z with y in the pins file and now it all works as it should, this was with the v1. 4. To use it you must have a Z probe (BL Touch, Inductive sensor, etc). But no matter what I do, I can't get the new probe to work. 006229. Collaborator. It is most useful when using a Trinamic stepper motor driver that has run-time configuration. This document describes how to use an eddy current inductive probe in Klipper. 022187, average 0. PROBE_CALIBRATE TESTZ Z=-3 # Instead of Z=-4 and Z=-1 ACCEPT SAVE_CONFIG. We would like to show you a description here but the site won’t allow us. This determines if Klipper should command the pin to move up between each probe attempt when performing a multiple probe sequence. cfg settings how far the X and Y axes can safely move without hitting the printer’s frame. I get a message of “Endstop z still triggered after retract” I’ve tried going through steps on this site (Connecting BL-Touch | klipper) but didnt work. cfg for the details). The log file has been engineered to answer common questions the Klipper developers have about the software and its environment (software version, hardware type, configuration, event timing, and hundreds of other questions). I also confirmed ground from Probe pin to octopus common ground. With the toolhead in the center of the bed, reconfirm that the probe is working correctly. , tried using the z endswitch (sensor_pin: ^PA7) with or without pullup) and tried using all 5 pin connector (sensor_pin: ^PB1 ,control_pin: PB0) gives me ‘BLTouch failed to verify sensor state’. The probe z_offset will then be calculated from these measurements. I have an MKS Robin Nano v1. Then while gently pushing the pin up slightly with the nail of your finger run QUERY_PROBE again. I have been struggling with the correct function of gantry leveling for days. I've tested the probe manually with a Jun 11, 2024 · klicky probe is installed on PIN PB7 (J40) and Z Endstop Switch on PIN PG10 (J31) which has been replaced in the printer config file with endstop_pin: probe:z_virtual_endstop. manual_probe. 1. Pasting your printer. I use an Creality 3d 1. EDIT: So digging around a little more. With Klipper, BLTouch probes automate the mesh bed levelling process. I am having trouble with the bltouch when homing. z_position} to find the current Z position. Tried swapping with brand new spare SB2209 (RP2040) and a spare new optical Looking for a quick sanity check. Wires on bltouch on board are plugged in this order We would like to show you a description here but the site won’t allow us. A rare number of old "clone" devices are unable to report when they have successfully raised their So I started off thinking my probe was not working as well in the probe port. It is connected to dedicated port for proximity sensor given in BTT Octopus at 24V. Jan 6, 2024 · Make sure that the printer geometry is correctly defined in your configuration file. Without the setting, the probe status is always triggered. In the bed mesh section you'll also need to adjust your Mesh_min and mesh_max positions to suit your bltouch location. Read on to learn how to set up and use the BLTouch with Klipper! Advertisement. Blue ( - ), Brown ( + ) and Black (signal). 6. I have a NPN NO 6-36V inductive probe with a voltage divider on the signal wire for a 5V signal. You have a cartesian, so your pins are correct. I get 5. 2 as well? I am too facing the same issue that required pin_up_touch_mode_reports_triggered: False to get the probe working. 1 (F446) klippy. It is mounted as per Voron Stealthburner guide. z_offset = distance between bed and nozzle when endstop is triggered. The following. Electrically, you could get some false readings if it's required and your aren't using it. It is installed on a Voron 2. If the printer does not stop, then quickly disconnect the power supply. Probe is working!) It' s an "closer" probe, so I invertet the z-min pin in klipper. 4 (8bit) Board. When a metal object is close to the probe, QUERY_PROBE should return “triggered”. It is recommended to set the z_offset to 0. If the signal is inverted Jan 26, 2023 · 05:18:07 // Klipper state: Ready 05:18:29 $ G28 05:19:12 // probe at Forums. Since you are using bat85 diode, you can connect it to any endstop port, and yes you can just move it from z MCU to main MCU. Verify the command reports “probe: TRIGGERED”. 5mm. 4 Fysetc Spider 1. 2 main board, runout sensor and BLTouch) and all worked well with Marlin. Start by declaring a probe_eddy_current config section in the printer. A rare number of old "clone" devices are unable to report when they have successfully raised their Apr 2, 2019 · Sounds like you need to enable the hardware pull up by putting the '^' in front of the pin name. Jan 8, 2024 · General Discussion. With config [probe] pin: PG15 = always triggered, ~!PG15 + !PG15 = always open. See the MANUAL_PROBE command for details on the SPEED parameter and the additional commands available while the tool is active. log If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. If the bed does not stop, panic, scream and reset your board before the tool-head smashes into your bed. And with triggering z axes probe it didnt make homing for z axes. I decided to replace it with an Omron TL-Q5MC2-Z inductive probe. Verify the command reports "probe: TRIGGERED". 2 was released only in Jan 2019 and the minor increment in number seems to reflect a firmware change. 01-0. The probe works with 6 to 36v and has 3 wires. Oct 3, 2023 · This Toolhead PCB is designed and open sourced by Hartk for use with Voron Stealthburner. PROBE_CALIBRATE [SPEED=<speed>] [<probe_parameter>=<value>]: Run a helper script useful for calibrating the probe's z_offset. When ı want to home all axes it home first x and y (normally) but then the z axis sensor being triggered. From reading the Tap manual I shouldn't need the 220 ohm resister or do I. • Especially for testing purposes and to make sure not to damage the printer reduce homing_speed = 200. A verified cfg can be found here: klipper/printer-creality-ender3max-2021. Automatic Z-Offset Calibration. Endstop Z and probe always Triggered. However, no matter what I do in Klipper, I cannot get it to work. 0, z=0. As the probe moves closer to the bed the resonant If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. run BLTOUCH_DEBUG COMMAND=touch_mode, run QUERY_PROBE, and verify that command reports "probe: open". Set probe z offset to zero. Nov 23, 2021 · Hey, i´m new to klipper and trying to configure an inductive probe. Though I was wary of this solution as it could give a false report of accuracy if there's a legit issue with the probe or bed. In Marlin I created and used an extra gcode-file with several commands like “M421 I3 J2 Dockable Probe. Installed A BTT SFS V2 on both a Trident and 0. Which effectively resulted in discarding any wildly incorrect probes (which was always the first). Hey. (messured by Multimeter . log klippy. I try to get my “PL-08N2 NPN NC” probe running on the Btt Octopus 1. log Fill out above information and in all cases attach your klippy. This document provides information on calibrating the nozzle's Z offset automatically. This origin is the beginning of the usable printer bed. 042813, minimum 0. 15. A couple more repeats to confirm gave the same result: The inductive probe will temperature drift! Attached are two console windows one cold and the other with hot air on the probe. I can manually push the pin up or use a command to move it up, it registers open. Status reference. Anyway, I am going to try to make a gap of sorts, e. What values do I put in, and where in the config file. zip file contains printer cfg and all of klicky config files. Config section is below. Klipper can help you and your machine produce beautiful prints at a fraction of the time. Death69; Jun 11, 2024; Voron May 6, 2023 · I removed the inductive sensor and replaced it back to the older capacitive sensor. Then I move z down until I have a successful paper test. Dockable probes are typically microswitches mounted to a printed body that attaches to the toolhead through some means of mechanical coupling. İt works at first but now it behave strange. Eddy Current Inductive probe. May 6, 2021 · To verify the probe is working I’d recommend: Move the bed away from the tool-head. probe accuracy results: maximum 0. Setting up Klipper with a SKR Mini e3 v2 and a BLTouch clone. In the following, we assume a Cartesian printer that follows the conventions of a Jul 29, 2020 · If you think there is a regression, try going back to the old code (for example, cd ~/klipper ; git checkout af981432f ; make ; sudo service klipper stop ; make flash ; sudo service klipper start). I have tried bed tilt calibration (printing on glass, and there is about a 2mm height difference Feb 4, 2024 · So finally Mark changed to code seemingly back to the original one and now the probe_accuracy behaves like expected with the following result for my BD-sensor: 14:49. As for getting the value in the original macro, you might be able to use a gcode_macro for a global variable, and storing the value there. md before May 30, 2022 · Sineos May 30, 2022, 3:25pm 10. Mar 16, 2020 · I include capacitive sensor to my ender3 to gain ABL feature. 020625, range 0. Test according to doc, if triggered is "open" and open is Feb 25, 2022 · I,m unsure on what to wire it as, be it the probe port directly, with diode on pg15 or 11, with a 4. Querying endstop status stow and deployed returned always TRIGGERED status and not able to do homing any more, changed to SuperPinda to fix my issues as currently no replacements showed on BIQU Store. 06 its the only thing stopping me finishing the build, also would the fact i plan to get a octopus pro board as the octopusi have it on For the pin and it stayed on it was actually just being tripped by the tube pulling on the sensor, I put the ! Back in the pin assignment and once I removed the tube I turned off the printer and turned it back on resetting the sensor and ran the mesh like that Oct 10, 2023 · I have it hooked up to the probe pin PC1 as per duet documentation. And with that setting, probe status is always open. Currently, an eddy current probe can not be used for Z homing. When I attach the probe the LED light on the board comes on. Try better after each configuration-change the homing itself. It’s a different port on the processor, not just a different bit . txt (12. It features a streamlined 2 piece design for easy assembly and service with support for multiple configurations. Read the directions in docs/BLTouch. cfg) from "sensor_pin: PC14" to "sensor_pin: ^PC14". However, if I run them again after some time, the readings are consistent within the set, but they report a different Z value to the previous PROBE_ACCURACY. You'll want to set your x and y probe offset to where ever your probe is located and also set your z offset properly for your own printer. rsforester; Nov 1, 2023; Voron Tap; Replies 1 Views 1K. Feb 7, 2022 · The issue can be corrected by changing line 13 of the provided config file (SKR-mini-E3-V3. 038906, standard deviation 0. 3 KB) Fill out above information and in all cases attach your klippy. log file. 0 to 100 or even 50. log file (use zip to compress it, if too big). 14:49. discourse. g. zip (2. im getting devation from 0. 21:17:10 rear left : x=56. I can stow and deploy all day long, and the probe works great as a Z-STOP as well. 10K Ohm or more). If the QUERY_PROBE commands in that test always produce the expected results and "BLTouch failed to verify sensor state" errors still occur, then it may be necessary to set pin_up_touch_mode_reports_triggered to False in the Klipper config file. Then try G28 for homing and manually trigger the CRtouch to assess that is correctly working. 2 board running klipper where I wanted to install a PNP NO induction probe I had in hand. cfg at master · Klipper3d/klipper · GitHub. With this enabled, manual Z offset or first layer calibrations are needless. The default config on the BTT GitHub is with the bltouch wired only to the z-probe connector, not split partly to the z-endstop connector. I wired the new probe into the same wiring harness I used for the previous probe, using the PROBE pins on the board. I have it hooked up to 24v on the top left always on connectors and the signal is hooked up to Z- (PA11). I'm running stealthburner with CW2 on my 2. I’ve changed the detection length but regardless of what number (I’ve tried 2. cfg. So if you use a negative value here, you say that when the endstop is triggered your nozzle is underneath your bed. Unfortunately the QUERY_PROBE command always returns open. No logos or anything - just 3D Touch. I've confirmed that the probe is getting 24V, ground is correct and the signal wire teases out to the mainboard via ohm meter. Inductive Probe Check (V1, Trident, V2, Switchwire, Legacy) Probe Testing . Do homing of z. Dec 23, 2022. May 31, 2021 · Getting Klipper setup on Ender 3 with 4. 4 KB) Hello - took the dive into using Klipper/Mainsail with my Vyper and have a Pi4 - trying to go through the steps to calibrate the Probe Z offset and bed mesh and get " ‘No trigger on probe after full movement’ message. Mar 30, 2023 · Tap triggered in Klipper with Canbus. A typical endstop switch has an accuracy of around 100 microns. first, since I have a delta, my endstops are max pins, 2, 15 and 19. The function of homing is carried out without problems, but when I run the G32, the Z_Probe triggers without touching an obstacle. Nov 25, 2021 · edited. The Klipper PROBE_CALIBRATE tool can be used to obtain this value - it will run an automatic probe to measure the probe's Z trigger position and then start a manual probe to obtain the nozzle Z height. This document describes Klipper's stepper phase adjusted endstop system. Jun 3, 2023 · If you keep polarity, the diode shouldn't matter. The probe has a 4th wire on it for "temperature", but Welcome to the Ender 3 community, a specialized subreddit for all users of the Ender 3 3D printer. cfg file. I have also moved the pins to the Z-endstop port and changed the For some reason the inductive probe would not trigger when connected to the mainboard, but when connected to GPIO it triggers successfully. Nov 11, 2018 · Z_offset value I have from marlin. I'm not familiar with that printer, but check to see if you need to use a pull up resistor with the leveling probe. [bltouch] sensor_pin: PC1 control_pin: PA15 stow_on_each_sample: False. Edit: Also make sure that your bed is sufficiently far away so that the probe can actually deploy. I tried moving it to a different port on the board, and changed the configuration to follow that port. #3. klippy. Some boards have a low # value pullup resistor on the Z probe input, which will likely result in an # always-triggered probe state. To check if the board works as it should, there is a diode, on the board that should trigger when TAP is lifted. You’re currently telling the printer to use the diag pin on the Z driver for sensorless homing which is not a safe way to home and could lead to a head crash. Trigger the probe with your finger. To enable this feature, one would determine the nozzle coordinates such that the Z probe is above the screws, and then add them to the config file. 1 MB) printer-cfg . Note: This should not be confused with probe location bias, which produces inaccurate results across the entire bed. cabinfourus June 26, 2022, 11:25pm 5. It also needs to know where the origin (X=0 / Y=0) is. The probe is working perfectly fine, I have checked it many Feb 19, 2023 · Hold some metal against the probe. May 3, 2024 · The ldc1612 inductive sensor operates similarly to traditional inductive sensors, except it provides more information on the measured “inductive resonance frequency”. the issue is that I can’t seem to get the head to retract far/fast enough from the bed post home. I have it connected to the GND of the probe connector (P0_10). Let's say, m114 reports - 3. Start homing. BTT SFS V2 False Detection…. Mar 28, 2020 · Run BLTOUCH_DEBUG COMMAND=pin_down, verify that the pin moves down, run BLTOUCH_DEBUG COMMAND=touch_mode, run QUERY_PROBE, and verify that command reports “probe: open”. 8ma. Connected the Brown wire on the left pin (DC=+v), the Blue wire to the middle pin (GND=OV), and the Black wire to the right pin (PB7=OUT). The LED on the sensor (Zhongde #PL-08N2 a NPN NC probe) lights up bright and stayed bright even with some metal up against it. 2. Now I switched to Klipper, and I run in the same problem. cfg is not needed Be sure to check our Knowledge Base and in particular this and this post Describe your issue:Can someone check out my cfg and log file, Trying SOLUTION: Connect all the 5 pins to the bltouch connector and use this config. However after the first probe, motion stops and I get a message stating "Probe triggered prior to movement". It computes always the correct offset independantly of the current temperature, used nozzle or used print bed or flex plate. com. I just converted a Ender 5 with some parts of a Ender 5 Plus (using the Creality v2. M119 reports X_MAX_ENDSTOP is triggered all the time (even when switch is manually closed) but when I invert it (X_MAX_ENDSTOP_INVERTING -> true), the printhead moves in the correct direction during auto-homing, but keeps crashing into the frame. by Andreas Giencke. 037125, median 0. Sep 23, 2023 · Tried shorting gpio21 directly to gnd and no change within Klipper. It did not look like there was a Klipper log file attached to this ticket. 1 schematic) is an opto-isolator with a forward current of 20ma typical. Dec 6, 2022 · electronics. The meshes are from, again, cold vs. Aug 14, 2019 · Hywelmartin commented on Aug 15, 2019. The z_offset is the distance between the nozzle and bed when the probe triggers. log (1. Published Dec 1, 2022. It's written in the example-config. The sensor can only be used for Z probing. Bat85 is there to protect the MCU from a probe failed in closed state with unexpectedly high voltage. Mar 8, 2023 · Basic Information: Printer Model: x5sa frame MCU / Printerboard: skr mini e3 v2 klippy. If you want to use the probe for homing you need to change the endstop_pin to probe:z_virtual_endstop. I think the PROBE_CALIBRATE command works just fine but then it crashes the build plate. I followed this guide from Reddit (got the cfg and Klipper firmware from that GitHub link) and the official Klipper docs. I have “pin_up_touch_mode_reports_triggered: True” in the The z_offset is the distance between the nozzle and bed when the probe triggers. puttin_in_w0rk February 21, 2023, 2:04am 9. At 24 volts the current would be 23. 2 board (F103) ANTCLABs BLTouch. However, if the # output pin is connected to the board pin with a pullup resistor, that # resistor must be high value (e. Mar 17, 2020 · Since I made the upgrade and rewired everything, the Z inductive probe doesn't work. It always reports "probe: open" or "probe: TRIGGERED" no matter what I do. 45. The fields in this document are subject to change - if using an attribute be sure to review the Config Changes document when upgrading the Klipper software. BUT, im having issues with sporadic "Timeout on Homing Z" errors while homing. My probe needs 10-36v . Check Klipper out on discord, discourse, or Klipper3d. When I run PROBE_ACCURACY, I get very consistent readings within that run. a completely warmed up machine that'd been heat-soaked for half and hour. 76000 : adjust CW 00:01. 3V on the signal line by lowering it via resistance. group” is an extended documentation of Klipper. Thinking this might be a speed issue, I have halved the speed, increased the hop height, this does not change anything. If that works, check your cfg it could be the wrong probe pin, it could be that you have to change the input behaviour. Klipper Z-Calibration on github refers to this youtube video: Apr 1, 2019 · Does anyone else happen to be running a genuine BLTouch v2. When it is far from the bed, QUERY_PROBE should return “open”. arvest March 22, 2024, 12:20pm 5. 487V. You have to run a voltage through the switch in order to turn the led on in the opto-isolator. 4 turbo and then again with v1. log (60. When probe stops, m114 reports z as 1. Tried a fresh install of Klipper from scratch, using up-to-date install then reloading config, no change. I've printed out the parts and installed the probe using the same wiring and Fysetc port (pin PA3) that I was using for the inductive probe Unfortunatly, after loading euclid. New posts so with the sensor bolted in with both screws it was stuck at triggered Feb 8, 2023 · I am having same issue, tried everthing the BLTouch. 2 board. I did everything in the documentation. the triggered/open status is changing as expected. Apr 5, 2022 · General Discussion. I am using the PL-08N2, direct into a BTT Octopus (via probe socket, if that Problems with probe calibration, inductive probe for a Neptune 3 Pro. The magnetic field at and around these magnets may cause an inductive probe to trigger at a distance higher or lower than it would otherwise, resulting in a mesh that does not accurately represent the surface at these locations. If the bed is cold, I don't seem to have an issue homing. When triggered, I have 0. Jan 8, 2024 · The X and Y Axis Klipper needs to know from its printer. Max2883 April 5, 2022, 8:07pm 1. pe yy bn fe cn hk yk qt rq rz