Hp switch disable port

Some other reserved TCP ports on the switches are 49, 80, 1506, and 1513. config. Port Security (Page 12-4). Disabling port security on a port: switch (config-if)# port-access port-security disable. For inbound traffic matching the filter type, determine the filter action you want for each outbound (destination) port on News and Events. Robert5205 (Robert5205) November 13, 2017, 11:06am 4. To select one or more ports to configure within a QSFP, you need PoE allocation by value and the maximum power delivered. 8 Spice ups. To configure a local mirroring session in which the mirroring source and destination are on the same switch, follow these general steps: Determine the session and local destination port: Session number (1-4) and (optional) alphanumeric name. On the ports you will use as authenticators, either accept the default 802. Under Manage, click Device (s) > Switches. Configure a non-default power threshold for SNMP and Event Log reporting of PoE consumption on either all PoE ports on the switch or on all PoE ports. XX, the USB port can be disabled and enabled without affecting the autorun feature. brief. HP Switch> show lacp LACP LACP Trunk Port LACP Admin Oper Port Enabled Group Status Partner Status Key Key ---- ----- ----- ----- ----- ----- ---- ----- Al Active Dyn1 Up Yes Success 100 100 A2 Active Dyn1 Up Yes Success 100 100 A3 Active Dyn1 Up Yes Success 100 100 A4 Active Dyn1 Up Yes Success 100 100 A5 Active Dyn1 Up Yes Success 100 100 A6 Active If this command is configured on a member port in an aggregation group, it takes effect only after the port leaves the aggregation group. Similarly, to configure a single port with the above command settings, you could either enter the same command with only the one port identified or go to the context level for that port and then enter To enable or disable selected switch ports: Select the Configuration > Ports > Ports page. ) For example, to enter the context level for port C6 and then configure that port for 100FDx: HP Switch(config)# int e c6 HP Switch(eth-C6)# speed-duplex 100-full If port C8 was disabled, and you wanted to enable it and configure it for 100FDx with flow-control active, you could do so with either of the following command sets: LLDP operation configuration options. Range: 0 - 65535 seconds. Just check what is causing the issue before you disable the switch. 0000x PortDescr : LAN Port System Capabilities Supported : bridge Configuring switch ports to operate as supplicants for 802. The manual mode setting that configures the port for connecting to either a PC or other MDI device with a crossover cable, or to a switch, hub, or other MDI-X device with a straight-through cable HP Switch (oobm)# interface enable HP Switch (config)# oobm interface disable Setting the OOBM port speed The OOBM port operates at 10 Mbps or 100 Mbps, half or full duplex. <port-list If you believe the question would be on-topic on another Stack Exchange site, you can leave a comment to explain where the question may be able to be answered. From the left-hand side, click on ‘Choose what the power buttons do’. <PORT-LIST>. When the USB port is enabled, the autorun feature activates if a USB device is already inserted in the USB port. Exit port (any port on the switch except a monitored interface used to HP-5406Rzl2(config)# no allow-v2-modules. Enabling an interface: switch (config-if)# no shutdown. 1X authentication on a port: switch (config-if)# aaa authentication port-access dot1x authenticator enable. Use the stp edged-port enable command to configure the ports as edge ports. Click Restart Now under Advanced startup. 1X user-based or port-based authentication on the individual ports you want to serve as authenticators. HP Switch(config)#: no qos device-priority 10. Use the undo stp edged-port command to restore the default. 1 Spice up. 168. Hi, thanks for your answer. 06. HP Switch(config)# show lldp info remote-device 1 LLDP Remote Device Information Detail Local Port : A2 ChassisType : network-address ChassisId : 0f ff 7a 5c PortType : mac-address PortId : 08 00 0f 14 de f2 SysName : HP Switch System Descr : HP Switch, revision xx. We would like to show you a description here but the site won’t allow us. Click the configuration icon to display the switch configuration dashboard. NOTE: HP recommends using the default IP port number (443). In the factory default state, the switch is enabled for up to 16 VLANs, all ports belong to the default primary VLAN and are in the same broadcast/multicast domain. The comptuer will reboot to a special menu. Default: 0. The LLDP configuration includes global settings, which apply to all active ports on the switch, and per-port settings, which affect only the operation of the specified ports. Feature Default Menu CLI Web viewing port status n/a page 10-6 page 10-7 page 10-17 configuring ports See Table 10-1 on pages 10-4 and 10-5. Description. x. Command Reference Content 01 Fundamentals Command Reference Covers the commands for logging in to and setting up the Switch. NOTE: For PoE, disabling all ports allows the 22 watts of minimum PoE power or the 38 watts for PoE+ power allocated To configure ports C1 through C3 and port C6 for 100Mbps full-duplex, enter these commands: switch (config)# int c1-c3,c6 speed-duplex 100-full. 20). Thank you i will try and post result here tomorrow. If you were to enable a disabled port you simply you use the enable command. CDP should be enabled and running on the interfaces to which the phones are connected. The following command displays the VLAN and per-port configuration resulting from May 3, 2016 · 05-19-2016 04:54 AM - edited ‎05-19-2016 05:09 AM. Set the default rule to "Allow". The Edit Power Over Ethernet Settings window is displayed. SSDP DDoS reflection attackers are abusing my iLo5 open port 1900 - but I cannot find anyplace in the settings to turn that off (which makes me very angry, because that is advertising my PRIVATE services and ports to the whole world too!). spiceuser-rrw40 (spiceuser-rrw40) March 11, 2022, 5:46am 3. so I have 2 switches at work: One is a ProCurve 2810-48G and the other is a 2530-48G. Product: HP DL325 G10. 59 and later software. The no form of the command disables PoE operation on <PORT-LIST>. Select a value: If admin-edge-port is disabled on a port and auto-edge-port has not been disabled, the auto-edge-port setting controls the behavior of the port. Disabling an interface: switch (config-if)# shutdown. 13. 1X connections to other switches. 254. Operating System: Linux. 2 Spice ups. 14. The automatic, default setting. This configures the port for automatic detection of the cable (either straight-through or crossover. The switch offers two methods for using 802. The rate-limit all command controls the rate of traffic sent or received on a port by setting a limit on the bandwidth available. 50. The default value of 0 (zero) sets an infinite timeout (that is, ports that are disabled by bpdu-protection are not, by default, re-enabled automatically). We’re primarily an HP shop from a server,desktop and laptop perspective and we’ve been working with HP Blade System for the past two years. You can get there by clicking the gear icon on the Start menu. 3. I tried the following commands for port 3: SWITCHNAME (eth3) (config): no aaa port-access authenticator quiet-period 0. Examples # In MSTP mode, disable the spanning tree feature on . For more information on features that use this command, refer to the Security Guide for your switch model. How to enable/disable a port in HP ProCurve Switch - Step by step with screenshots. Online connectivity is OK and working fine when directly connected via hardwire to Linksys router (or via wifi) Ethernet 1 port (on Linksys) connect to Cisco 3550 fa0/24 (switch has basic configuration, no VLANS, all ports are on default VLAN1) HP switch connected to Cisco 3550 port fa0/23. select the playback tab. Select Update & security. Login HP Switch Web Utility. HP Switch(config)#: spanning-tree 1-10 bpdu protection HP Switch(config)#: spanning-tree trap errant-bpdu The following steps will then be set in progress: When an STP BPDU packet is received on ports 1-10, STP treats it as an unauthorized transmission attempt and shuts down the port that the BPDU came in on. Enter CLI and type “configure” to enter config mode. HP Switch (vlan-1)# ip igmp auto 1,2 forward 3,4 blocked 5,6. PARTNERS HPE GreenLake; HPE Complete Care Service; HPE Tech Care Service; HPE Proactive Care Service; HPE Foundation Care Service; Services at a Glance Configuring local mirroring. SWITCHNAME (config): no aaa port-access authenticator 3 quiet-period 0Result: Invalid input This HP-proprietary TCP/IP port on the printer is the default port for printing. As with many Data Centers we’ve been deploying a large number of blade servers and switches. -Select your site. If port C8 was disabled, and you wanted to enable it and configure it for 100FDx with flow-control active, you could do so with either of the following command sets: Enabling 802. the HP 5120 EI Switch Series, software release train 2215. Result: Invalid input: aaa. Continue (y/n)? When V2 compatibility mode is enabled from disabled state, the below message is displayed for user input. Click Interface > PoE. Highlight the Port you want to enable or disable. If not already selected, select the fabric and the switches to edit. That is if the 2920 supports it. 5-4 Using a Standalone Web Browser in a PC or UNIX Workstation . Then, click on the link ‘Change settings that are currently unavailable’. 119 key source0119 HP Switch# show radius Status and Counters - General RADIUS Information Deadtime(min) : 0 Timeout(secs) : 5 Retransmit Attempts : 3 Global Encryption Key : Dynamic Authorization UDP Port : 3799 Source IP Selection (mode) mismatch. The CLI configures and displays port-based and protocol-based VLANs. HP actually OEM’s two different GbE2 switches for their Blade enclosures. In the default configuration, LLDP is enabled and in both transmit and receive mode on all active ports. right click on sound video and game controllers. -click on done. 62 show ntp statistics. I want to change it into the access port. hope this helps. Select the port (s) you want to edit and click Edit. 1X authentication on a port: switch (config-if)# aaa authentication port-access dot1x authenticator disable. stp global enable. 1X-authenticated client on a port, which opens the port to an unlimited number of clients. Before configuring loop guard. I wanted to delete the particular port configuration and wanted to reconfigure it. Select Recovery from the left menu. Configuring traffic/security filters. 1. -click on the port you want to shutdown (net & power). In the Table view, scroll and select pages as needed and click on the port check box (es) to select ports to configure. However, on a per-port basis, you can HP Switch 2920-series (J9726A, J9726A, J9727A, J9727A, J9728A, J9729A) If you cannot access the switch after a software version downgrade, clear the password by using the Clear button on the switch to regain access. Switch A Switch A Port Security Configured Switch B MAC Address Authorized by Switch A PC 1 MAC Address Authorized by Switch A Physical Topology Logical Topology for Access to Switch A • PC1 can access Switch A. I have HP 5500 L3 switch. Next we need to set up root bridge priority on your core switch (s). To select one or more ports to configure within a QSFP, you need Jun 10, 2021 · 06-02-2021 07:32 PM. Configure port security. -click on port details. save. Click Configuration and then Port Configuration. Default: All PoE ports are initially enabled for PoE operation at Low priority. Deleting and disabling 802. The prompt for this mode includes the identity of the selected port(s): HP Switch(config)# interface c3-c6 HP Switch(eth-C5-C8)# HP Switch(config)# interface trk1 HP Switch(eth-Trk1)# . ). Support Center. Lists a subset of configuration data for all ports on the switch; that is, for each port, the display shows whether the port is enabled, the operating mode, and whether it is configured for flow control. <Sysname> system-view [Sysname] interface [Sysname-] undo stp enable Related commands. I’ll check it out on Monday! This is the maximum amount of power that will be delivered. Specify the port priority you want Jan 4, 2008 · HP GbE2 Switch Blade. I 08/21/12 09:37:21 ports: port A20 is now off-line. HP Switch(config)# logging origin-id ip-address HP Switch(config)# no logging origin-id hostname HP Switch(config)# no logging origin-id none The following syslog message will occur: <14> Jan 1 00:15:35 169. Configuring a rate limit of 0 (zero) on a port blocks all traffic on that port. Then create a custom service. For software versions K. This command will disable all V2 modules and reboot the switch. right click on the headphones and select disable. Sep 15, 2013 · Internal LAN scheme is 192. Closed 11 months ago. Configuring the switch for SSH operation. ) Mar 10, 2022 · 2 Spice ups. Use the cdp enable and cdp run commands. pfarrell (PatrickFarrell) April 14, 2021, 3:24pm 3. I 08/21/12 09:37:39 ports: port A20 is Blocked by STP. When I look in the switch log I see following entries: I 08/21/12 09:37:20 ports: port A20 is Blocked by STP. Power is synchronized with the enabling and disabling of USB ports as described above for K. That is, any device can access a port without causing a security reaction. If you wish to reenable it, you will need to open Device manager. By default, all ports are non-edge ports. Add MAC address of every authorized device. At a minimum, HP recommends that you always assign at least a manager password to the switch. HP Switch(config)# show power-over-ethernet A6 Status and Counters - Port Power Status for port A6 Power Enable : Yes LLDP Detect : enabled Priority : low Configured Type : AllocateBy : value Value : 15 W Detection Status : Delivering Power Class : 2 Over Current Cnt : 0 MPS Absent Cnt : 0 Power Denied Cnt : 0 Short Cnt : 0 Voltage : 55. 1X access control. int x enable to turn it back on. 5-4 The Menu interface enables configuration and display of port-based VLANs only. 1. benjaminmease (Honest Bob) October 7, 2016, 8:45pm 11. When in service policy page, choose create a new service. Disabling 802. HP 2610 Switch Series - Disabling Loop-protect Disables Ports. Syntax: Configures the duration of time when protected ports receiving unauthorized BPDUs will remain disabled. However, if this is the desired behavior on the port, HP recommends using the <port-list> disable command instead of configuring a rate limit of 0. Feb 27, 2015 · The first thing to do is to select your root bridge (the central most switch in your network). 1X settings or change them, as necessary. Since the command set is different from Cisco, can anyone help me? One more thing I want to add, currently that port is configured as trunk port. To enable or disable selected switch ports: Select the Configuration > Ports > Ports page. . 18. Mar 26, 2014 · click on sound/manage audio devices. Ports A1 and A2 have been previously configured for a static LACP trunk. -click on your switch. STP used to prevent loops. 1X authentication configuration on a port: switch (config-if)# no aaa v Starting a Web Browser Interface Session with the Switch . Title of the question is pretty explanatory, is there a way to turn off the Setting up port security includes several steps: Plan port security. HP Switch> show lacp LACP LACP Trunk Port LACP Admin Oper Port Enabled Group Status Partner Status Key Key ---- ----- ----- ----- ----- ----- ----- ----- Al Active Trkl Up Yes Success 0 250 A2 Active Trkl Up Yes Success 0 250 Dec 8, 2020 · On your keyboard, press ‘Windows key + R’ and type ‘Powercfg. A Dynamic LACP trunk with one standby link. LPD: Line Printer Daemon (LPD) refers to the protocol and programs associated with line-printer spooling services that may be installed on various TCP/IP systems. Before configuring Loop Guard on port 20, the status of VLAN 20 appears as follows: HP Switch(config)#: show spanning-tree vlan 20 Spanning Tree Information STP Enabled [No] : Yes Mode : RPVST Extended System ID : Enabled Ignore PVID Inconsistency : Disabled Switch MAC Address : 002347-c651c0 VLAN ID : 20 RPVST Enabled : Enabled Root MAC Address : 0024a8-d13a40 Port Information Mode Unknown VLAN Status ----- ----- ----- ----- 5 Untagged Learn Up 6 Tagged Learn Up 8 Untagged Learn Up 18 Untagged Learn Down 22 Untagged Learn Up 26 Tagged Learn Up hp-procurve Share May 17, 2016 · I’m pretty sure it’s something like lldp admin-status disable, off the top of my head, in the CLI it would be something like. HP Switch (oobm)# interface enable HP Switch (config)# oobm interface disable Setting the OOBM port speed The OOBM port operates at 10 Mbps or 100 Mbps, half or full duplex. The default port security setting is Off. Hit the ‘Enter’ key to open power options in the control panel. For an example of using this command Mar 30, 2016 · HP Procurve Switch 2626 disable/enable interfaceCommands:Conf tinterface port's disable/enablewrite memory (save configuration)exit We would like to show you a description here but the site won’t allow us. Then enter “spanning-tree” to enable it. • PCs 2 and 3 can access Switch B and Switch C, but are blocked from accessing switch A by the port security settings in switch A. 2. The HP 1810 series switches can be managed in-band from a remote network station using a web GUI, and its configuration may also be viewed using the SNMP manager. The “User-Based” method supports up to 32 802. int x disable. 63 Port Configuration: The default port configuration is Auto, which enables a port to sense speed and negotiate duplex with an auto-enabled port on another device. Port 9100 is an HP-proprietary raw TCP/IP port on the HP Jetdirect print server and is the default port for printing. 236 00076 ports: port 2 is now on-line ntp trap. Depending on the privilege level, you could use one of the following commands to configure IGMP on VLAN 1 with the above settings: HP Switch (config)# vlan 1 ip igmp auto 1,2 forward 3,4 blocked 5,6. Causes the switch to send an SNMP trap to a network management station and disable the port. HP Switch(eth-1-3, 5)# no int 5 monitor HP Switch(eth-1-3, 5)# no monitor HP Switch(config)# no int 5 monitor HP Switch(config)# no int 1-3, 5 monitor These two commands show how to disable monitoring at the interface context level for a single port or all ports in an interface context level. 5. The PoE page is displayed. The pre-standard-voice option for the cdp mode command allows the configuration of CDP mode so that it responds to received CDP queries from a VoIP phone. Otherwise, under some circumstances, anyone with Telnet, web, or serial port access could modify the switch configuration. Aug 21, 2012 · Hello! I have the CSE-H53 Serial-Ethernet-Converter from the company Sollae on a HP 4200vl (L11. 104 HP Switch(config)#: qos dscp-map 000100 priority 6 HP Switch(config)#: int 3 qos dscp 000100 HP Switch(config)#: qos udp-port 1260 priority 2 Reconfigure the desired priority for the 000001 codepoint. 4. This feature enables you to configure each switch port with a unique list of the MAC addresses of devices that are authorized to access the network through that port. use the no switch to turn it back off. Similarly, if the same port negotiates a 10 Mbps link, then it allows no more than 5 Mbps of inbound traffic. Generally, the “Port Based” method supports one 802. HP Switch(config)# radius-server host 10. or in interface context: HP Switch (eth-A6) # poe-allocate-by value. Configured in Ethernet interface view, the setting takes effect only on Jan 1, 1990 · Example of a show LACP listing. It is accessed by HP software (for example, the HP Standard Port). Lists the current operating status for all ports on the switch. -click on the devices button. Jan 18, 2018 · Click that, then go to Advanced options > UEFI Firmware Settings > Restart. Using the commands described in this chapter, you can: Enable or disable PoE operation on individual ports. Use this procedure to specify the type of filters to use on the switch and whether to forward or drop filtered packets for each filter you specify. The device use port A20. Use the stp edged-port disable command to configure the ports as non-edge ports. To configure a port by value: Set the PoE allocation by entering the poe-allocate-by value command: HP Switch (config) # int A6 poe-allocate-by value. We have all HP Procurve switches. If you moved the cable to another port, it would work. Dec 23, 2014 · Networking. The lights would blink, and there would seem to be a connection, but it didn’t work. For example, to enter the context level for port C6 and then configure that port for 100FDx: HP Switch(config)# int e c6 HP Switch(eth-C6)# speed-duplex 100-full. Then issue the following command (note you can tab complete) interface ethernet 13 disable. Apr 3, 2015 · Log into your switch via console (in my case I SSH in using Putty) When connected type: configure. Start creating a rule. auto-mdix. Assign a local login (operator) and enable (manager) password. To check the mode setting for a port on the switch, use either the Port Status screen in the menu interface (page 10-6) or show interfaces brief in the CLI (page 10-7). Specifying the traffic rate as either a percentage of bandwidth, or in terms of kilobits per second. This command will erase the current configuration of the switch and reboot it. Otherwise, you must manually ensure that the mode setting for each port in a trunk is Configuring a global MAC authentication password HP Switch(config)# aaa port-access mac-based password secretMAC1 HP Switch(config)# show port-access mac-based config Port Access MAC-Based Configuration MAC Address Format : no-delimiter Password : secretMAC1 Unauth Redirect Configuration URL : Unauth Redirect Client Timeout (sec) : 1800 Unauth Redirect Restrictive Filter : Disabled Total PoE operation. That’s all you need to do on a switch to get STP up and running. show interfaces [brief | config | < port-list >] brief. 22. Newsroom HPE Discover Events Webinars. 230. This command reference includes: • CLI (command privilege settings and CLI management commands) • Login in to the switch • FTP • TFTP client example, in this command syntax, you must provide one or more port numbers: Syntax: aaa port-access authenticator PORT-LIST Command Prompts In the default configuration the Series 5400zl switches, for example, display one of the following CLI prompts: ProCurve Switch 5406zl# ProCurve Switch 5412zl# Learn how to configure the HP Switch Port Mirroring feature using the web interface, by following this simple step-by-step tutorial, you will be able to configure the port monitor feature using an HP Switch. Otherwise, flow control does not operate on the link and appears as Off in the show interfaces brief port listing, even if flow control is configured as enabled on the port in the switch. Steps: Access IPsec/firewall. (Default: Disabled. (See Show interfaces brief command listing. HP-5406Rzl2(config)# allow-v2-modules. This enables individual ports to detect, prevent, and log attempts by unauthorized devices to commu nicate through the switch. This guide describes how to configure and view the software features using the Web-based graphical user interface (GUI). HP V1810 Switch Series - How to Enable/Disable a Port. 26. stp mode. If you configure a higher priority, this priority is retained until you change it. Select the static filter type (s). Via Cloud Managed/App. Monitor PoE status and performance. Enabling port security on a port: switch (config-if)# port-access port-security enable. Default: No - disabled The no form of the command disables edge-port operation on the specified ports. Click Enable selected Ports or Disable Selected Ports. FTP Printing. 15. HP Switch(config)# show port-access mac-based clients 1 detailed Port Access MAC-Based Client Status Detailed Client Base Details : Port : 1 Session Status : authenticated Session Time(sec) : 6 Username : client1 MAC Address : 0010b5-891a9e IP : n/a Access Policy Details : COS Map : 12345678 In Limit % : 98 Untagged VLAN : 4006 Out Limit HP Switch(config)#: spanning-tree 1-10 bpdu protection HP Switch(config)#: spanning-tree trap errant-bpdu The following steps will then be set in progress: When an STP BPDU packet is received on ports 1-10, STP treats it as an unauthorized transmission attempt and shuts down the port that the BPDU came in on. ) Also, the port (speed-duplex) mode must be set to Auto (the default. You can disable port 221 using IPsec/firewall option under "Networking" tab. Includes port-or trunk-specific commands that apply only to the selected port(s) or trunk group, plus the global configuration, Manager, and Operator commands. int e {port_number_here, eg port c2} lldp admin-status disable. -wait for sync to complete. It includes options for: Rate-limiting on either inbound or outbound traffic. Enable or disable File Transfer Protocol services available on the HP Jetdirect print server for printing. Today I came in and half the office is down, all over the Jan 2, 2020 · 3. Oct 7, 2016 · Enable the BPDU-Filter for that port and it will remain in forwarding mode, thus essentially turning off STP for that port only. Apr 14, 2021 · I would like to know the commands to turn on/off a specific port# in a Aruba 2530 model switch. cpl’ in it. However, you can use web-management ssl tcp-port to specify any TCP port for SSL connections except those reserved for other purposes. da-schmoo (Da_Schmoo) April 14, 2021, 2:31pm 2. stp vlan enable User Authentication Methods. Choose "All IP address" for Address policy. 127 key source0127 HP Switch(config)# radius-server host 10. HP Switch recommends that you use the Auto setting for all ports you plan to use for trunking. Enable 802. (For more on the Active parameter, see LACP port status data. ) mdi. Navigate to settings. If you rebooted the switch all ports would work fine…. One switch kept getting “dead” ports. For more information on features that use this command, refer to the Fundamentals Guide for your switch model. click on the IDT HIgh Definition Audio Codec and right click and uninstall. Nov 13, 2017 · That’s the reason the ports are blocking. chuongluu2 (chuong6133) May 17, 2016, 10:46am 3. . If you subsequently re-enable the port without clearing the port's intrusion flag, the port blocks further intruders, but the switch does not disable the port again until you reset the intrusion flag. Syntax: spanning tree port-list auto-edge-port no spanning tree port-list auto-edge-port Untrusted port COS (type 0x13): 0x00. STP blocks the ports that are causing the loop, for example, two ports are causing the loop then STP blocks one port from them. For an example of using this command HP Switch(config)# fault-finder link-flap ethernet A1-A5 action warn-and-disable 65535 sensitivity high Configure ports for link-flap detection with medium sensitivity Configure ports A8 for link-flap detection with sensitivity of medium (6 flaps over 10s) and to log and disable port if the link-flap threshold is exceeded. -click on active toggle. HP Switch(config)# fault-finder link-flap ethernet A1-A5 action warn-and-disable 65535 sensitivity high Configure ports for link-flap detection with medium sensitivity Configure ports A8 for link-flap detection with sensitivity of medium (6 flaps over 10s) and to log and disable port if the link-flap threshold is exceeded. Modify and delete MAC Address settings, as necessary. Examples of reserved IP ports are 23 (Telnet) and 80 (http). 1X-authenticated clients on a port. I do NOT want or use UPnP or SSDP at all. zw wv od hw ts qq qa la tl gw